General Server Requirements & Precautions

These are the general precautionary requirements for optimal operation of the QP®.

  • Determine the placement of each component in the rack before you install the rails.

  • Install the heaviest server components on the bottom of the rack first and then work upwards.

  • Use a regulating uninterruptible power supply (UPS) to protect the server from power surges, voltage spikes and to keep your system operating in case of a power failure.

  • Allow the hot plug hard drives and power supply modules to cool before touching them.

Always keep the rack’s front door and all panels and components on the servers closed when not servicing to maintain proper cooling.

Ambient Operating Temperature

If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperatures (TMRA).

Reduced Airflow

Equipment should be mounted into a rack to that the amount of airflow required for safe operation is not compromised.

Mechanical Loading

Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading.

Reliable Ground

A reliable ground must be maintained at all times. To ensure this, the rack itself should be grounded. Particular attention should be given to power supply connections other than the direct connections to the branch circuit (i.e. the use of power strips, etc.).
To prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety:

  • This unit should be mounted at the bottom of the rack if it is the only unit in the rack.

  • When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the heaviest component at the bottom of the rack.

  • If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in the rack.

Power Supply Specifications:
Safety Listings:

USA - UL listed, FCC
Canada - CUL listed
Germany - TUV Certified
Europe/CE Mark
EN 60950/IEC 60950-Compliant


Server Operating Environment (across all models)

Operating Temperature Range: 5°C ~ 35°C (41°F ~ 95°F)

Non-Operating Temperature Range: -40°C ~ 60°C (-40°F ~ 140°F)

Operating Relative Humidity Range: 8% ~ 90% (non-condensing)

Non-Operating Relative Humidity Range: 5% - 95% (non-condensing)